SA41 ELECTRICAL SPECIFICATIONS
INVERTER TYPE PWM Full bridge power stage, with true sine wave AC output.
DEMAND START SECTION
Type: Pulsing AC
Minimum Load Power to start (User adjustable): 3W to 20W
Maximum response time: 1 sec
Standby current from battery (Average): 60mA
BATTERY VOLTAGE RANGE
Low DC Volts Disconnect (Instantaneous): 34V
Low DC Volts Cutout (Delayed, User Adjustable): 38-44V
Low DC Volts Cut-in (Delayed, User Adjustable): 44.4-52V
High DC Volts Cutout (Instantaneous, User Adjustable): 60-68V
High DC Volts Disconnect (Instantaneous): 70V
TOTAL APPLIANCE RATING AT 25°C 40°C
Continuous: 3000W 2800W
30 Minute rating: 4700W 4400W
5 Minute rating: 5300W
1 Minute rating: 6500W
Surge rating: 8500W
INVERTER EFFICIENCY
Peak (at 500W): 91%
No load power consumption (C0NT mode): 0.66 A
MISCELLANEOUS SPECIFICATIONS
Output Frequency Accuracy: 50Hz ± 0.001 %
Output Voltage Accuracy (0 - 2200W) 240V ± 4 %
Total Harmonic Distortion (THD) < 4 %
Control Outputs 1 & 2, max DC sinking current: 50 mA
Alarm Inputs 1 & 2, input switching level: HI > 3 V
LO < 1 V
Operating temperature range: -10°C to 50°C
Weight: 32 kg
DC Input is Electrically Isolated from AC Output
Note: Through a policy of continued development, specifications are subject to change without
notice.
The above specifications are based on unity power factor.