Note that the controller can only be set to LO A/H and CO+LAH if the optional external current shunt
kit (SA-S200) is used. Each controller output is capable of switching an external relay or contactor
which can be used to switch AC or DC loads.
If the controller is set to INV CO, LO A/H or CO+LAH and the condition still exists after the
"Duration" time, the output will stay on until the condition ends. Also with these settings a "Lockout"
option can be set ON or OFF. (See lockout below and on page 11)
LOCKOUT
DURATION
On with : INV CO
[Set Control 1]
On with : LO A/H
[Set Control 1]
On with : CO+LAH
[Set Control 1]
Lockout: ON
[Set Control 1]
Duration : 4 Hrs
[Set Control 1]
Duration : 30 Min
[Set Control 1]
(Inverter Cut out) The control 1 output will turn on when the inverter shuts
down due to overload, over temperature or low or high voltage.
The output will remain on for the time set in "Duration", below.
The output will not come on if the front panel circuit beaker is tripped.
(Low Amp-Hours) If the charge in the batteries falls below the level set in
the "Minimum Charge" setting (see page 13), then the control output will
come on, for the time set in "Duration", below.
(Cutout or Low Amp-Hours) This setting combines the previous two, bring
the output on with low amp hours, or with the inverter cutting out.
The output will stay on for the time set in "Duration", below.
If set to ON, lockout prevents the controller output coming on during the
lockout period. (See notes on lockout on page 11.) Pressing the UP or
DOWN keys will change the setting.
This screen sets the duration hours the control 1 output will stay on.
Pressing the UP or DOWN keys will change the setting.
This screen sets the duration minutes the control 1 output will stay on.
Pressing the UP or DOWN keys will change the setting.