4.1.6 Returning all parameters to standard default setting
Setting the standard default setting parameter V[R to 3, all parameters can be returned to the
those factory default settings.
Note: For more details on the standard default setting parameter V[R, see 5.3.
Notes on operation
We recommend that before this operation you write down on paper the values of those
parameters, because when setting V[R to 3, all parameters with changed values will be
returned to standard factory default setting.
Steps for returning all parameters to standard default setting
Key operated LED display Operation

Displays the operation frequency (perform during operation
stopped).
CWJ The first basic parameter "History (CWJ)" is displayed.
V[R Press the key or the key to change to V[R.
  
Pressing the ENTER key displays the programmed
parameters. (V[R will always display zero "" on the
right, the previous setting on the left.)
  
Press the key or the key to change the set value. To
return to standard factory default setting, change to "".
KPKV
Pressing the ENTER key displays "KPKV" while returning
all parameters to factory default setting.
P Turn the power on.
P
Select a parameter among P, R and P, using
the and keys. Select P in this case.
KP KV
Press the ENTER key to confirm your change.
When KP KV is displayed, you can set the setup
parameter.
 The operation frequency is displayed (Standby).
 The operation frequency is displayed again.
If there is something that you do not understand during this operation, press the key
several times and start over again from the step of CWJ display.