Features
2–2 975-0263-01-01
Front Panel
Side View
Feature Description
1 Detachable remote panel to display inverter status and battery status information. For
more information about the remote panel, see “Front Panel Operation” on page 4–2.
2 GFCI receptacles provide 1000 W (XM 1000) or 1800 W (XM 1800) of power to operate
AC devices. The GFCI receptacles can be removed to access the AC wiring compartment
for hardwiring the inverter to an existing AC power system.
3 Knockouts for routing AC input and output wiring in hardwired installations.
4 Mounting flange allows you to mount the inverter permanently.
Feature
Description
1 15 A supplementary circuit breaker provides overload protection for the GFCI
receptacles. In a hardwired installation, the supplementary circuit breaker does not protect
output wiring.
2 Grounding stud connects to vehicle chassis, DC grounding bus or to engine’s negative
bus.
3 Cooling fans (XM 1800 only) turn on when powering loads above 500 W, or when the
internal temperature rises above 113 °F (45 °C).
RESET
TEST
TEST
RESET
2
4
1
3
XM 1000 shown
1
2
3