Xantrex Technology XM 1800 Marine Battery User Manual


 
Over-temperature Conditions
975-0263-01-01 4–7
Over-temperature Conditions
When the XM 1800 senses its internal temperature approaching its limit,
the alarm beeps every two seconds and the display shows fault code E07
alternating with “OtA”.
If the over-temperature condition persists, the XM 1800 shuts down to
protect itself. The alarm beeps once per second and the display shows
fault code E08 alternating with “Ot”.
Routine Maintenance
XM 1800 Unit
Minimal maintenance is required to keep your XM 1800 operating
properly. Periodically you should:
Clean the exterior of the unit with a damp cloth to prevent the
accumulation of dust and dirt.
Ensure that the DC cables are secure and fasteners are tight.
Make sure the ventilation openings are not clogged.
Batteries
When possible, you should recharge your batteries whenever a low
voltage shutdown occurs with the XM 1800. This gives the batteries a
much longer life than recharging when the batteries have been almost
completely discharged. For more information on maintaining batteries,
see “Battery Tips” on page B–7.
For information about Xantrex battery chargers, see our web site at
www.xantrex.com.
Important:
If you are unsure about operating any device with the XM 1800,
contact the manufacturer of the device.