Installation
3–10 975-0263-01-01
Materials The following checklist is a general list of required materials.
❐ Four corrosion-resistant fasteners sized #10 (M4.5) for mounting the
inverter
❐ Copper DC input cable as calculated in Table 3-1 on page 3–7
❐ Two 3/8 inch (M8) ring terminals sized for the cable diameter to
connect the DC cables to the DC cabling terminal
❐ Lugs and terminals to connect the DC cables that connect to the
battery, disconnect/battery selector switch and fuse holder(s)
❐ DC fuse(s) as calculated in “Calculating Fuse/Circuit Breaker Size”
on page 3–8 and fuse holder(s)
❐ Copper chassis ground cable as specified in Table 3-2 on page 3–7
❐ Ring terminal (appropriately sized to connect copper cable to chassis
ground stud) that meets the following specifications:
• #8 (M4) stud
•UL/CSA approved
• copper
• tin-plated
❐ Battery isolator (if connecting to a multiple-battery system)
❐ Disconnect/battery selector switch
❐ Optional: 2 × 15 A circuit breakers (XM 1000) or 2 × 20 A circuit
breakers (XM 1800), used for hard wiring the AC input and AC
output to an existing AC circuit.
❐ Optional: Multi-stage alternator regulator
1
❐ Optional: High-output alternator
1
1.Consult Appendix B, “Battery Types” and Appendix C, “Alternators and Charging
Systems” to determine whether you need these components.
Important:
The product comes with the items listed on page 2-1. If you have
lost any of these items, an accessory kit of fasteners is available under Xantrex
part number 808-7119. Please visit www.xantrex.com/buy.asp to order.
Xantrex_PRO1800.book Page 10 Tuesday, April 24, 2007 11:33 AM