XM 1000 XM 1800
Output power at 77 º F (25 ºC) ambient
temperature and 12 VDC input:
Maximum continuous output power
•5 minutes
1000 W
1200 W
1800 W
n/a
Surge rating 2000 W 3600 W
Output voltage 115 VAC RMS ± 10
Output waveform Modified sine wave
Output frequency 60 Hz ± 1 Hz
DC input voltage range 10.5–15.5 VDC
DC low voltage alarm 11.0 V
DC low voltage cutout 10.5 V
DC low voltage recovery 12.0 V
Over-voltage cutout 15.5 V
AC pass-through low voltage cutout 90 V
AC pass-through low voltage recovery 100 V
Optimum efficiency 90%
No load power draw with inverter on < 5 W < 9 W
No load power draw with inverter off < 1 W