Xantrex Technology XM 1800 Marine Battery User Manual


 
AC Wiring
975-0263-01-01 3–19
11. Insert the Line and Neutral wires into the corresponding terminals.
12. Tighten the wire attachment screws to a torque of 1.3–1.8 lbf-ft (1.76–
2.44 Nm). Leave some wiring slack inside the wiring compartment.
Ensure you have maintained correct polarity and that there are no loose
strands of wire.
13. Secure the strain-relief clamp.
14. Attach the wiring compartment cover.
15. Connect the outgoing AC wires to the AC load panel.
CAUTION: Reverse polarity
Improper connections (connecting a line conductor to a neutral conductor, for
example) will cause the XM 1800 to malfunction and may permanently damage
the inverter. Damage caused by a reverse polarity connection is not covered by
your warranty.
Xantrex_PRO1800.book Page 19 Tuesday, April 24, 2007 11:33 AM