A SERVICE OF

logo

Programmer’s Guide, cont’d
MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide
4-22
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Information requests
Information request I
V
X2^
X
X2&
•A
X2^
X
X2&]
V(video)matrixsize•
A (audio) matrix size
Request part number N
X2*]
See appendix B for part
numbers.
N
There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which
istheoverallcontrolrmware;theEthernetprotocolrmware,whichhandlestheEthernetinterface;andthelatest
optional Extron firmware update, which is available at www.extron.com.
Query controller firmware
version
Q
X2(]
Example:
Q
1.23
]
The factory-installed
controller firmware version
is 1.23 (sample value only).
Query controller firmware
version (verbose)
0Q
X2(
-
X3)
-
X3)]
Provide a detailed status of
the MTPX Plus controller
firmware and any firmware
upgrade. The firmware that
is running is marked by
an asterisk (*). A caret (^)
indicates that the firmware
has a bad checksum or an
invalidload.?.??indicates
that firmware is not loaded.
Responsedescription:Ethernet protocol firmware version-controller firmware version-updated firmware version
]
Example:
0q
Ethernet protocol
firmware
1.23-1.00(1.06-16x16Series-Tue,04Dec200700:00:00GMT)-1.00*(1.06-16x16Series-Thu,27Dec200616:39:21GMT)
Description
MTPX firmware version
Updated firmware version
* indicates the version running Upload date and time
Request system status S
X3!
X3!
X3!
X3!
X3!
X3@
X3#
X3#]
Responsedescription:+3.3V+5V-5V+12V-12Vtemperature (degrees fahrenheit)Fan 1 speedFan2speedFan3speed
]
N
Fansarenumbered1,2,and3,fromreartofront.
Example:
3.28•+4.98•-5.01•+11.52•-12.35•+086.80•03590•03668•03627
Fan 1 (rear) rotating at 3590 RPM3.3V power system at 3.28V
+12V power system at 11.62V
N
X2^
=Numberofinputs 8,16,or32
X2&
=Numberofoutputs 8,16,or32
X2*
=Partnumber 60-nnn-nn
X2(
= Firmware version number to second decimal place (x.xx)
X3)
= Verbose firmware version-description-upload date/time
X3!
= Voltage Positive or negative voltage and magnitude
X3@
= Temperature Degrees Fahrenheit
X3#
= Fan speed RPM