Furuno 2827wd Marine RADAR User Manual


 
5. INPUT/OUTPUT DATA
5-3
AIS transponder equipment
One serial input interface (IEC 61993-2 Ed.1 message !XXVDM, message types 1, 2, 3,
4, 5, 6, 9, 12, 14, 18, 19, 21 and 24, min 1 message per 10 seconds)
Notes:
Max. 1500 simultaneous AIS targets can stored for display purposes.
Max. 240 simultaneous AIS targets out of 1500 stored can be displayed.
When own ship’s VDO message is not received, the message “737 AIS receiver error”
appears in the text window.
Alarm ACK inputs
Input from alarm system (Contact closed is No Alarm)
ACK sentence from alarm system (IEC61162-1)
Alarm outputs
RADAR system failure as open contact (Contact closed is No Failure)
ANY RADAR ALARM as open contact (Contact closed is No Alarm)
OPERATOR FITNESS notice as closed contact (Contact open is No activity)
ALR (alarm data) for alarm system (IEC61162-1)
External interfaces
Positioning equipment
One additional positioning equipment
Alarm outputs
ROUTE MONITOR: OUTSIDE CHANNEL LIMITS alarm as open contact (Contact closed
is No Alarm)
ROUTE MONITOR: WAYPOINT APPROACH alarm as open contact (Contact closed is
No Alarm)
ECHO: DEPTH BELOW LIMIT alarm as open contact (Contact closed is No Alarm)
NAVIGATION SENSOR ALARM as open contact (Contact closed is No Alarm) from B
adapter