Furuno csh8l SONAR User Manual


 
8. MAINTENANCE, TROUBLESHOOTING
8-8
8.8.2 Description of diagnostic tests
Single test, Conti(nuous) test
The single and conti(nuous) tests check the ROMs and RAMs for proper operation,
one time or continuous, respectively. After the test is completed, the results are indi-
cated as OK (normal operation) or NG (malfunction), to the right of the device
checked. For the single test, normal operation is restored after completion of the test.
When the MENU key is pressed in the continuous test, the equipment goes into start
up condition.
Continuous test (example: CSH-5L, 55 kHz transducer)
CONTI TEST
MAIN-0 1050729-XX.XX F FF
ROM = OK
RAM = OK
VRAM = OK
EEPROM (P.W) = OK
TRX 1050
***
-XX.XX 1050###-XX.XX FF FF
ROM = OK
RAM = OK
DROM = OK
KEY-0 1050730-XX.XX F
ROM = OK
RAM = OK
PRESS [MENU] KEY TO EXIT
Processor unit's program version no.
and results of ROM, RAM, VRAM
and EEPROM tests.
0 = Version No. of Board
Transceiver unit's program
version no. (CSH-5L only)
and results of ROM, RAM
and DROM* tests.
* = Continuous test
only
Control unit's program
version no. and results
of ROM and RAM tests.
0 = Version No. of Board
XX.XX: Program Version No.
*** : 742 (CSH-5L 55 kHz, 68
kHz)
735 (CSH-8L 85 kHz)
736 (CSH-8L 107 kHz)
### : 733 (CSH-5L 55 kHz)
734 (CSH-5L 68 kHz9
735 (CSH-8L 85 kHz)
736 (CSH-8L 107 kHz)
F : DIP SW setting