Furuno csh8l SONAR User Manual


 
SP - 2 E1319S01E-M
Note
1) Ranges shown for off-center “on” are maximum value.
2) Under certain circumstances, a target (fish school) may not be detected
due to its nature or because of sea conditions, ever if it is located within
the display range.
2.6 Pulse-length 0.5 to 20 ms, interlocked with range (can be changed in 11 steps)
2.7 Pulse repetition rate (PRR)
0.25 to 4.4 s, interlocked with range (can be changed in 11 steps)
External synchronized transmission keying
2.8 Audio search
Method By external loudspeaker
Sector 20°, 40°, 80° and 120° selectable
Output 2 W
Frequency 800 Hz (CSH-5L), 1 kHz (CSH-8L)
3 HULL UNIT
3.1 XDCR travel 600 or 400 mm, selectable
3.2 Raising/lowering time 400 mm: 14 s, 600 mm: 20 s
3.3 Driving system Remote electric control
3.4 Allowable ship’s speed 18 knots max. (16 knots during raise/lower operation)
4 INTERFACE
4.1 Input data NMEA 0183 Ver1.5/2.0/2.2
GGA, RMC, GLL, VHW, VTG, HDG, HDM, HDT, DPT, DBT, DBS,
CUR, VDR, GLC, GTD, MTW, RMA
4.2 Log, E/S, KP Speed log pulse (contact signal): 200/400 pulse/NM
Sonde, E/S signal: VI-1100A applicable
External KP: Current loop, 0 to 12V
4.3 Output data NMEA 0183 Ver1.5/2.0/2.2 TLL
4.4 Video signal output
Method RGB analog, separated synchronization, XGA (VESA)
Resolution 1024 x 768, 65.0 MHz clock
Frequency of vertical/horizontal 60 Hz/ 48.36 kHz
Connector D-sub15P-female
4.5 CIF data input Location, Ship’s Speed, Bearing, Current data (1 Layer),
Water depth, Water temperature, Multiple layer current data
5 POWER SUPPLY
5.1 Processor unit
CSH-5L 100/115/200/220/240 VAC: 4.0-2.0A, 1 phase, 50-60 Hz
CSH-8L 100/115/200/220/240 VAC: 4.5-2.2A, 1 phase, 50-60 Hz
5.2 Inverter Required for 24 VDC
6 ENVIRONMENTAL CONDITION
6.1 Ambient temperature 0°C to +50°C
6.2 Relative humidity 95% at 40°C
6.3 Degree of protection
Processor/ control unit IPX2 (w/o connector panel of processor unit)