Furuno FCV-295 SONAR User Manual


 
12
6. Press T to select "Transducer" and then press the ENTER key. The list of programmed trans-
ducers appears.
7. Press T to S select transducer connected and then press the ENTER key.
8. Jot down the alphabet which appears on the "Tap" line. You may need to change the tap set-
ting at the rear of the display unit depending on the transducer type which is connected. For
details, see below.
9. If a low frequency transducer is fitted, repeat steps 2 to 8.
Note: Leave the "Tx Power" setting at "Auto".
10.Press and hold down the [ /BRILL] key to turn off the power.
Note: To confirm the transducer selection after completion of the setting, turn on the power
while pressing any key. Release the key after the “XDCR Setting” dialog box appears.
Tap setting
Set the tap according to the alphabet shown when you selected transducer type.
200B-5S
50/200-1T
50/200-1ST
200B-8B
200B-12H
(Example: 200 kHz)
Display unit rear panel
(connector cover removed)
Tap setting plug
(for high frequency)
E D C B A
Common point
Tap setting plug
(for low frequency)
Set this end in applicable slot according to
alphabet indication.
jumper
connection