Furuno FCV-295 SONAR User Manual


 
13
Entering transducer data by transducer specifications
To connect the transducers which are not programmed, do as follows:
Note: The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to
the FCV-295 because of noise.
1. At the XDCR Setting dialog box, select "XDCR Select" and press the ENTER key.
The following screen appears.
2. Press T to select "Manual", and then press the ENTER key.
3. If a high frequency transducer is fitted, press T to select "HF Connection" and then press the
ENTER key.
4. Press S to select "Connected" and then press the ENTER key.
5. Press T to select "Freq" and then press the ENTER key.
6. Press T or S to set the frequency of the transducer which is connected and then press the
ENTER key.
7. Press T to select "Band width" and then press the ENTER key.
8. Press T or S to set the value for the bandwidth and then press the ENTER key. If the band-
width is not entered manually, it is automatically set to 1/10 of the transducer frequency.
9. If a low frequency transducer is fitted, repeat steps 3 to 8.
Note: Leave the "Tx Power" at "Auto".
10.Press and hold down the [ /BRILL] key to turn off the power.
3.3 Speed/Water Temperature Sensor Calibration
If the optional speed and/or water temperature sensor is connected, set it up as follows:
1. Turn on the power and press the MENU key.
The main menu and sub-menu appear.
2. Press T to select "System" and "Calib" and then press the ENTER key.
XDCR Type
Manual
Connected
Not connected
--- kHz