Furuno FR-2155 Marine RADAR User Manual


 
1-12
KB BOTTOM
PLATE
P312 FX Connector
P314 XH3P
J312 (underside)
J314 (underside)
Screw
M4X8 (8 pcs.)
Pan-head Screw M4X8 (2 pcs.)
Be careful not to pinch cable between
KB clamp and spacer.
Spacer
KB Clamp
KB Fixing Plate
Lay cable in slot.
Earth Wire
Upset Screw
M6X12 (2 pcs.)
Handle
Replace with
cable assy. in
kit.
Figure 1-15 Control head
Connection of display unit to control head
1. Attach the handle to the handle plate, using the screws for the handle and
bottom cover of the control head.
2. Attach the handle plate to location where the KB arms were fastened.
3. Pull the monitor toward you until you hear click.
4. Lead in the cable assy. (option) from the rear entrance of the display unit. See
Chapter 2.
5. Raise the monitor and fix the stay.
6. Inside the display unit, fasten ground wire of the cable assembly with an M4
screw on the chassis.
7. Plug in two connectors of connection cable (P412, J583: See illustration on the
previous page.)