3-8
3.4 Other SYSTEM Menu Items
This section shows you how to set up external equipment. Default settings are
underlined.
3.4.1 INTERFACE SETTING menu
INTERFACE SETTING
CIF BAUD RATE : 4800 bps
MENU QUIT
QUIT
AUX BAUD RATE : 19200 bps
NMEA 2 BAUD RATE
: 4800 bps
NMEA 1 BAUD RATE
: 4800 bps
EXT KP INPUT
: DISABLE
EXT KP OUTPUT
: NEGATIVE
INTERFACE SETTING menu
NMEA 1 BAUD RATE
Set the transmission rate for the NMEA 1 port.
(2400 bps, 4800 bps
, 9600 bps, 19200 bps)
NMEA 2 BAUD RATE
Set the transmission rate for the NMEA 2 port.
(2400 bps, 4800 bps
, 9600 bps, 19200 bps)
CIF BAUD RATE
Set the transmission rate for the CIF port. (2400 bps, 4800 bps
, 9600 bps, 19200
bps) If the CS-120A is connected, select “2400 bps”.
AUX BAUD RATE
Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps,
19200 bps
)
EXT KP INPUT
Select whether the KP signal from external equipment is used or not, and set the
edge polarity. (DISABLE
, POSITIVE, NEGATIVE)
Note: Set TX INTERVAL in H-SCAN SETTING menu to “0” for transmission with
external kp signal.
EXT KP OUTPUT
Select the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE
)