Furuno GD-1920C-BB Marine RADAR User Manual


 
2-7
2.2.3 Power requirement, replacement of fuses
Power requirement
The power for the power supply unit and display unit must be drawn from the same power
switch on the power terminal board.
Other Equipment
(ex. GPS, E/S, etc.)
Ship's power terminal board
Power supply unit
PSU-008
Other Equipment
(ex. GPS, E/S, etc.)
Other Equipment
(ex. GPS, E/S, etc.)
Other Equipment
(ex. GPS, E/S, etc.)
Other Equipment
(ex. GPS, E/S, etc.)
POWER
DATA 3
NETWORK
CONT DATA 1
DATA 2
DJ-1
SLAVE DISPLAY
RGB OUT
NTSC/PAL
2
GND
3
INPUT
12-24 VDC
1
CARD SLOT
3
2
1
GND
F.G.
12 VDC
OUTPUT
OPTION
Processor unit
Power supply unit
PSU-005
Wiring processor unit and power supply board to power terminal board
Replacement of the fuse
The power supply unit is shipped with a 15 A fuse. Replace the 15 A fuse with a 7 A fuse
(supplied) when the ship’s battery is 24 VDC. The fuse in the processor unit is also 15 A.
Replace it with a 3A fuse.