3-8
29. Choose the height of the antenna above the water surface and then press the C:
ENTER soft key.
30. Choose STC CURVE and then press the C: EDIT soft key.
STC CURVE
{
NARROW
~
NORMAL
{
WIDE
31. Choose appropriate STC curve setting and then press the E: RETURN soft key.
NARROW: The effective range of the A/C SEA adjustment is relatively short.
NORMAL: Between NARROW and WIDE.
WIDE: The effective range of the A/C SEA adjustment is relatively long.
32. If you are going to use the equipment as a remote display, choose MONITOR
MODE and then press the C: EDIT soft key. If not, go to step 34.
MONITOR MODE
{
ON
~
OFF
33. Choose ON and then press the C: ENTER soft key.
TX blanking function is not available when the MONITOR MODE is ON. To set a TX
blanking sector, select OFF from MONITOR MODE on the NavNet equipment, and
then set the sector same as the main radar. Finally, set MONITOR MODE to ON.
When the MONITOR MODE is ON, the following functions are not available.
Tuning (auto/manual, on the RADAR SETUP menu)
Antenna rotation (RADAR SETUP menu)
TX sector blanking (RADAR DISPLAY SETUP menu)
Watchman (RADAR DISPLAY SETUP menu)
Pulse select (Soft key)
34. Choose HEADING ADJUST and then press the C: EDIT soft key.
HEADING ADJUST
{ ON
~ OFF