Furuno NAVPILOT-500 Marine Instruments User Manual


 
2. BASIC OPERATION
2-4
2.4.2 Selecting the data shown on Normal Display 2, Data Display
and Graphic Display
Display modes may be set up to suit your operating needs as below.
Selecting data
In the STBY mode, you can select which data you want to display in the columns
shown in the figure below. For Normal Display 1 and 2, you may choose which
data you want to show on the analog indicator.
STBY
20.5
HDG
145.9
HDG
STBY
20.4
116.5
Data Display*
HDG
STBY
20.4
116.5
Graphic Display
Normal Display 2
Analog indicator column
STBY
20.5
HDG
145.9
Normal Display 1
Data column
*: Two or three data can be selected on installing.
1. Press the [STBY] key to show the STBY mode.
2. Press the [STBY] key several times to show the one of screens shown above,
which you want to change the data.
3. Press the course control knob.
The first column is circumscribed with a rectangle.
4. Press the [PORT] or [STBD] key to select the column desired.
Note that there is one column in the Normal Display 1 and Graphic data.
5. Rotate the course control knob to select the data you want to show.
Available data and analog indicators are listed on the next page.