Graco 249881 Marine Instruments User Manual


 
Service
22 309497L
Replacing the Bezel
Bezel Repair Kit 246438 is available and can be ordered
separately. See the Parts List for the 246008 and
249881 Electronic Meters on page 33. The parts with a
next to their reference numbers are included in this
repair kit.
When repairing the meter using the Bezel Repair Kit, be
sure to use all of the new parts. To replace the parts do
the following.
1. Relieve the Pressure.
2. Remove the battery (11). See Parts Drawing for
the 246008 and 249881 Electronic Meters on
page 32.
3. Slide the rear boot (24) off the hose.
4. Remove the meter from the fluid hose.
5. Remove the impact guard (40) from the meter.
6. With a phillips screwdriver remove the four phillips
screws (42) holding the bezel to the cover halves
(18 & 19). See F
IG. 24.
7. With a T-10 torx driver remove the remaining eleven
screws (12) holding the cover halves together (18 &
19).
8. Pull apart the two cover halves leaving all parts in
the right cover half (18). See F
IG. 25.
All services to the meter should be done using the
right cover half (18) of the meter. If parts should disen-
gage as the covers are separated, reposition the parts
back into the right cover half (18).
CAUTION
Be sure to use the disposable grounding wrist strap
included with the repair kit. Static electricity can dam-
age the electrical components as the meter is
repaired.
WARNING
To reduce the risk of serious injury whenever you are
instructed to relieve pressure, always follow the Pressure
Relief Procedure on page 8.
FIG. 24
F
IG. 25
42 (both sides)
12
19
18