CAUTION
Failure to comply with the following installation
requirements may result in warranty coverage
being denied.
Fluid lines MUST be thoroughly flushed before
installing Matrix meters
. See CleanLine Filtration
System, Instruction Manual 310652.
All Matrix systems MUST use the Graco Clean-
Line System for initial flushing and ongoing oper-
ation for all service fluids. See CleanLine
Filtration System, Instruction Manual 310652.
Pressure relief kits MUST be used on all pumps
within the Matrix system to prevent over-pressur-
ization due to thermal expansion. See Pressure
Relief Kits, Instruction Manual 308403. Select
appropriate relief kits when using high pressure
(1600 psi) CleanLine filters. Low pressure (900
psi) CleanLine filters have a built-in pressure
relief valve.
KEY DESCRIPTION, See F
IG. 3.
D
Thermal Pressure Relief Kit must be
installed downstream from the pump. The
Thermal Pressure Relief Kit will vary based
on the pump selected
E Fluid shut-off valves (two)
F Air Regulator
G CleanLine Filter System
HPump *
J Filter and Lubricator Assembly
K Master Bleed Air Valve (ball valve)
* Do not use diaphragm pumps in a Matrix system.
† Special pump packages are required for anti-
freeze. See instruction manual 310650.
FIG. 3
D
E
F
G
H
J
K
ti5127