Graco 249881 Marine Instruments User Manual


 
Service
26 309497L
14. Insert the RF Board (103) into the new right meter
half (18). See F
IG. 35.
Ensure that the RF Board (103) is positioned
securely in the slots (A) of the new right meter half (18).
See F
IG. 35.
15. Slide the trigger assembly (13, 14, 22, 23, 36, & 37)
back onto the mounting peg on the right half of the
meter (18). See F
IG. 36.
Ensure that the circular trigger plunger (23) is cen-
tered with the trigger switch. Also ensure that the trigger
spring (37) is securely slid into position. See F
IG. 36.
16. Make sure that all other meter parts are positioned
securely and in the correct location. See F
IG. 37.
17. Attach the bezel (31) to the right meter housing (18).
F
IG. 34
F
IG. 35
F
F
E
E
D
103
101
A
FIG. 36
F
IG. 37
Ensure that all meter parts are positioned securely
and in the correct location. Ensure that all cables
are routed correctly throughout the meter and will
not be pinched or kinked when the halves are reas-
sembled See F
IG. 38 and FIG. 39.
23
37
ti4323