Graco A-25 Outboard Motor User Manual


 
Setup
3A1569B 15
Setup
Locate Reactor A-25
1. Locate Reactor A-25 on a level surface and bolt in
place to the floor with 3/8 in. (10 mm) bolts, unless
the Reactor needs to remain portable.
Two bolts through the 2 in. (50 mm) deep caster
bushings in the rear.
Two bolts through the 3-5/8 in. (168 mm) deep
caster bushings in the front.
2. Do not expose Reactor A-25 to rain.
3. If you need to move the machine, add
optional wheel kit.
4. Lift with hoist only from bar spanning across top of
cart.
Determine Power Source
Reactor A-25 can be wired to 3 types of power source:
230 Volt / 1 Phase
230 Volt / 3 Phase Delta (3 wire + ground PE)
380 Volt / 3 Phase WYE (4 wire + ground PE)
(220 Volts to Neutral)
Electrical Requirements
NOTE: Power cord is not supplied.
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician connect power and
ground to main power switch terminals and
ground lug.
Ensure your installation complies with all National,
State, and Local safety and fire codes.
Ensure that incoming power is disconnected and
locked out at the source.