Graco A-25 Outboard Motor User Manual


 
Setup
16 3A1569B
Configure to Supply Power
NOTE: Both cord connection AND jumper positioning
steps on page 17 must be completed.
Step One - Connect Electrical Cord
NOTE: Disregard terminal numbers on disconnect
switch blocks. Wire to positions shown. Terminals will
accept up to #8 AWG (10 mm
2
) conductors.
1. Using a flat screw driver, turn cover fasteners 90°
counterclockwise. Lift and pull the front cover away.
2. Connect main power cord to electrical console as
follows:
a. Feed power cord through strain relief (SR) on
right side of unit. Push black die release lever
(RL) down to release contacts block (PD) for
easy wiring.
NOTE: Strain relief accepts cords 0.59 to 1.0 in. (15-25
mm) diameter.
b. Connect power leads to Power Disconnect
Switch (PD). Snap contacts block (PD) back
onto switch.
c. Tighten strain relief nut.
d. Connect ground wire to ground lug (GL).
3. Replace lower front shroud. Reinstall the two
screws retained in Step 1.
230V, 1 Phase: Use a screwdriver to connect two power
leads to the top two middle terminal positions as shown.
Connect green to ground (GND). See page 17 for proper
jumper positions.
NOTE: Disregard terminal numbers on disconnect
switch blocks. Wire to positions shown.
230V, 3 Phase Delta: Use a screwdriver to connect
three power leads to top three left terminals as shown.
Connect green to ground (GND). See page 17 for
proper jumper positions.
380V, 3 Phase WYE: Use a screwdriver to connect four
power leads to the top terminals as shown. Connect
neutral only to N. Connect green to ground (GND). See
page 17 for proper jumper positions.
SR
PD
GL
RL
ti17570a