Graco A-25 Outboard Motor User Manual


 
Park
26 3A1569B
Park
Park the pumps at the end of the day to cycle propor-
tioner pumps to home position, submerging displace-
ment rod.
1. Open the park valve.
2. Trigger the gun until pumps stops at the bottom and
relieves pressure.
3. Close the air motor shutoff valve.
4. Close the park valve.
Pressure Relief
Procedure
The Fusion AP gun is shown.
1. Turn off feed pumps and agitator if used.
2. Park component A pump. Follow Park; see page 26.
3. Close the air inlet valve.
4. Trigger spray gun until gauges read zero.
5. Engage gun piston safety lock.
6. Close gun fluid inlet valves A and B.
7. Close pump inlet supply valves.
Shutdown
1. Turn main heater power OFF .
2. Follow Park; see page 26.
3. Check and fill wet-cups (AK, Z).
4. Follow gun shutdown procedure. See gun manual.
Close
Open
ti2409a
ti2421a
ti17716a