Icom IC-M802 Marine Radio User Manual


 
4 - 3
4-2 PLL UNIT ADJUSTMENT
LPL LOCK
VOLTAGE
HPL LOCK
VOLTAGE
REFERENCE
FREQUENCY
1
2
1
2
1
2
Operating frequency : 0.5000 MHz
Mode : J3E
Receiving
Operating frequency : 0.4999 MHz
Receiving
Operating frequency : 29.9999 MHz
Mode : J3E
Receiving
Operating frequency : 0.0300 MHz
Receiving
Wait for 5 minutes after power ON.
Terminate P5201 on the PLL unit to
ground with a 50 resister.
Receiving
PLL
PLL
PLL
Connect a digital multi
meter or oscilloscope
to check point
CP5301.
Connect a digital multi
meter or oscilloscope
to check point
CP5401.
Connect an RF volt-
meter to check point
P5201.
Connect a frequency
counter to check point
P5201.
1.0 V
Less than 4.0 V
4.2 V
More than 0.8 V
Maximum level
63.999990 MHz
([USA], [CAN])
64.000000 MHz
([OTH])
PLL
PLL
PLL
C5305
Verify
C5521
Verify
L5203,
L5204
X5251
([USA],
[CAN])
C5294
([OTH])
ADJUSTMENT ADJUSTMENT CONDITIONS
UNIT LOCATION
VALUE
UNIT ADJUST
MEASUREMENT ADJUSTMENT