Mitsubishi Electronics HF-KN Outboard Motor User Manual


 
A - 3
CAUTION
Do not carry the servo motor by holding the cables, shaft, encoder, or connector.
Install the servo amplifier and the servo motor in a load-bearing place in accordance with the Instruction
Manual.
Do not get on or put heavy load on the equipment.
The equipment must be installed in the specified direction.
Do not install or operate the servo amplifier and servo motor which have been damaged or have any
parts missing.
Do not block intake and exhaust areas of the servo motor with a cooling fan. Otherwise, it may cause a
malfunction.
Do not drop or strike the servo motor. Isolate it from all impact loads.
Securely fix the servo motor to the machine. If being attached insecurely, the motor may come off during
operation.
When handling the servo motor, be careful about the edged parts such as the corners of the servo motor.
Be sure to measure the motor vibration level with the servo motor mounted on the machine when
checking the vibration level. A great vibration may cause the early damage of a bearing, encoder, and
brake. The great vibration may also cause the poor connector connection or bolt looseness.
For the gain adjustment at the equipment startup, check the torque waveform and the speed waveform
with a measurement device to check that no vibration occurs. If the vibration occurs due to high gain, the
vibration may cause the early damage of the servo motor.
Take safety measures, e.g. provide covers, to prevent accidental access to the rotor of the servo motor
during operation.
Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. Otherwise,
the encoder may malfunction.
Do not subject the servo motor shaft to more than the permissible load. Otherwise, the shaft may break.
When you keep or use the equipment, please fulfill the following environment.
Item Environment
Operation 0 ˚C to 40 ˚C (non-freezing)
Ambient temperature
Storage -15 ˚C to 70 ˚C (non-freezing)
Operation 80 %RH or less (non-condensing)
Ambient humidity
Storage 90 %RH or less (non-condensing)
Ambience
Indoors (no direct sunlight), free from corrosive
gas, flammable gas, oil mist, dust, and dirt
Altitude 1000 m or less above sea level
HF-KN series X, Y: 49 m/s
2
HF-SN52/HF-SN102/HF-SN152 X, Y: 24.5 m/s
2
Vibration resistance
HF-SN202/HF-SN302 X: 24.5 m/s
2
Y: 49 m/s
2