Oceanic 04-8930-24 Scuba Diving Equipment User Manual


 
50
OCL OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
CAN BE USED AS
• Watch
Dive Computer (Air or Nitrox)
Digital Depth Gauge/Timer
Free Dive activity
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm.
No Deco limits closely follow PADI RDP.
Decompression in agreement with Buhlmann ZHL-16c and French MN90.
No Deco Deep Stops - Morroni, Bennett.
Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik.
Altitude - Buhlmann, IANTD, RDP (Cross).
Altitude corrections and O2 limits based on NOAA tables.
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ±1% of full scale
Timers 1 second per day
Dive Mode Activation:
• Must be in Dive Computer mode, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Wet Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters)
Dive Counter:
NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet).
Resets to Dive #1, upon diving (after 24 hours with no dives).
Dive Log Mode:
Stores 24 most recent NORM/GAUG dives in memory for viewing.
After 24 dives, adds 25th dive in memory and deletes the older dive.
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation.
Measures ambient pressure every 30 minutes in Watch mode, when Dive Computer mode is accessed, and every 15 minutes while in DC Surface
modes.
Does not measure ambient pressure when Wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
(1) 3 vdc, CR2032, Lithium battery (Panasonic or equivalent)
Shelf life Up to 7 years when shipped from factory in deep sleep mode.
Replacement User (annual recommended).
Use Life 1 year or 300 dive hours if (2) 1 hour dives per day.
Battery Indicator:
Warning - icon on solid when <= 2.75 volts, Battery change recommended.
Alarm - icon on ashing when <= 2.50 volts, change the Battery, will not function as a DC.
Operating Temperature:
Out of the water - between 20 °F and 140 °F (-6 and 60 °C).
In the water - between 28 °F and 95 °F (-2 and 35 °C).
BAR GRAPHS:
TLBG segments
• No Deco Normal zone 1 to 3
• No Deco Caution zone 4
• Decompression zone 5 (all)
VARI 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
• Caution zone 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (ashing) 5 (all) > 30 > 9 5 (all) > 60 > 18
SPECIFICATIONS