Oceanic 4.6271 Scuba Diving Equipment User Manual


 
27
VTX OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5382-r01 (10/24/14)
NO DECO MAIN, information includes** (Fig. 40A/B):
> Current Depth with FT (or M) icon.
> Dive Time Remaining (hr:min) with NDC (or OTR) icon.
> Graphic GAS 1 (or 2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG when
no Transmitter is in use (SPG = Submersible Pressure Gauge).
> Gas Time Remaining (min) with icon, up to 99 (remains at 99 when greater), blank if SPG.
> DS icon - if Deep Stop is set ON and has triggered (activated).
> TLBG (TL), VARI (AR) - if they apply.
> Low Battery icon - yellow (if voltage is at the warning level), or red flashing (if voltage is at the alarm level).
A (2 sec) - to access Adjust Brightness.
A (< 2 sec) - to access ALT.
M (2 sec) - to access the Gas/TMT Switch Menu*.
M (< 2 sec) - to apply a snapshot Earmark to the PCI data recorded at that time. The graphics EARMARK APPLIED will be
displayed in place of NDC for 3 seconds (Fig. 40C).
S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
S (2 sec) - to access Compass*.
*These items can only be accessed while viewing the Main.
ADJUST BRIGHTNESS, information includes (Fig. 41):
> xx % (last value saved). Up to 60% max when Low Battery Warning or Alarm.
S (2 sec) - to step back to the Main without changing the value.
A (< 2 sec) - to step upward through values of 10% to 100% one at a time in increments of 10%.
M (< 2 sec) - to step down through values one at a time.
S (< 2 sec) - to save the % setting and revert to the Main.
Revert to Main in 10 sec, if no button is pressed.
NO DECO ALT, information includes (Fig. 42):
> MAX D = xxx FT (or xx.x M).
> TIME = hr:min with AM (or PM) if 12 Hour Format.
> TEMP = xx F (or C).
> GAS 1 (or 2, 3, 4) = AIR; or FO2 % set with PO2 Alarm setting.
> PO2 = x.xx (current level).
> O2 SAT = xx % (current level of saturation).
A (< 2 sec) - to access DS Preview if On and triggered, or revert to Main.
M (< 2 sec) - to step back to Main.
Revert to Main in 10 sec, if no button is pressed.
DEEP STOP (DS) PREVIEW (if On and triggered), information includes (Fig. 43):
> Current Depth with FT (or M) icon.
> Graphic DEEP STOP with Stop icon (arrows and bar).
> Stop Depth with FT (or M) icon and countdown Time as 2:00 (min:sec).
A (< 2 sec) - to revert to Main.
M (< 2 sec) - to step back to ALT.
Revert to Main in 10 sec, if no button is pressed.
DEEP STOP (DS) MAIN, information includes (Fig. 44A):
> Current Depth with FT (or M) icon.
> Graphic DEEP STOP with Stop icon (arrows and bar).
> Stop Depth with FT (or M) icon and countdown Time (min:sec).
> Graphic GAS 1 (or 2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG.
> Gas Time Remaining (min) with icon, up to 99 (remains at 99 when greater), blank if SPG.
> TLBG (TL), VARI (AR) - if they apply.
> Low Battery icon - yellow (if voltage is at the warning level), or red flashing (if voltage is at the alarm level).
A (2 sec) - to access Adjust Brightness.
A (< 2 sec) - to access DS ALT (similar to No Deco ALT).
M (2 sec) - to access the Gas/TMT Switch Menu*.
M (< 2 sec) - to apply a snapshot Earmark to the PCI data recorded at that time. The graphics EARMARK APPLIED will be
displayed in place of Stop information for 3 seconds (Fig. 44B).
S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
S (2 sec) - to access Compass*.
*These items can only be accessed while viewing the Main.
Fig. 40A - NO DECO MAIN
(FO2 set for Nitrox)
Fig. 42 - NO DECO ALT
Fig. 43 - DS PREVIEW
FFT
GAS 1
95
AR
TL
SPG
0:38
NDC
0:17
EDT
Fig. 40C - NO DECO MAIN
(during 3 sec message)
FT
GAS 1 GTR
PSI
1480 42
86
AR
TL
DS
0:24
NDC
0:35
EDT
Fig. 40B - NO DECO MAIN
(no Transmitters in use)
TIME =
TEMP =
MAX D =
GAS 1 =
PO2 =
O2 SAT =
123 FT
3:41 PM
73 F
32%, 1.40
0.64
38%
98
FT
FT56 2:00
DEEP STOP
100%
ADJUST BRIGHTNESS
Fig. 41 - BRIGHTNESS
F
47
FT
GAS 1
GTR
PSI
1750
23
DEEP STOP
FT
46 1:38
TL
Fig. 44A - DS MAIN
FT
GAS 1 GTR
PSI
1480 42
86
AR
TL
E A R M A R K
A P P L I E D
F
47
FT
GAS 1
GTR
PSI
1750
23
TL
E A R M A R K
A P P L I E D
Fig. 44B - DS MAIN
(during 3 sec message)