Oceanic 4.6271 Scuba Diving Equipment User Manual


 
58
VTX OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5382-r01 (10/24/14)

Good (> 2.75 v) >> no Battery icon is displayed. No restrictions surface or dive..
Warning (<= 2.75 v) >> Low Battery icon (yellow) solid on Surface and Dive Mains, Battery change recommended. Brightness level automatically
limited to 60% maximum.
Alarm (<= 2.50 v) >> Low Battery icon (red) ashing on Surface and Dive Mains. Graphics GO UP LOW BATTERY with Up Arrows ashing on Dive
Mains, graphics CHANGE BATTERY (red) ashing on Surface Mains until the unit the shuts off. Must change the Battery.

Warning (<= 2.75 v) >> graphic BATT LOW (yellow) solid on BATT, TMT STATUS screen, Battery change recommended.
Alarm (<= 2.50 v) >> graphic TMTx LOW BATTERY (red) alternating with graphic NORM (or GAUG, or FREE) on Surface Main. Change the Battery.
Alarm (<= 2.50 v) >> graphic BATT LOW (red) ashing on BATT, TMT STATUS screen. Change the Battery.

Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
In the water >> between 28 °F and 95 °F (-2 and 35 °C).

 segments
• No Deco Normal zone 1 to 6 (green)
• No Deco Caution zone 7 to 9 (yellow)
• Decompression zone 10 (red)
 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone (green) 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone (green) 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone (green) 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone (yellow) 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (red) 5 (all ash) > 30 > 9 5 (all ash) > 60 > 18
 Range: Resolution:
Time of Day 0:00 to 23:59 hr:min 1 minute
PC/Mac Countdown Timer 2:00 to 0:00 min:sec 1 second
Altitude Level Sea, EL-2 to EL-7 1 (level)
Time to Fly 23:50 to 0:00 hr:min 1 minute
Time to Desaturate 23:50 to 0:00 hr:min 1 minute
Temperature 0 to 99 F (-18 to 60 C) 1 F (C)
Depth, Max Depth (display) 0 to 330 FT (100 M) 1 FT (0.1 M )
Tank Pressure 0 to 5000 PSI (345 BAR) 5 PSI (1 BAR)
NORM, GAUG Surface Interval 0:00 to 23:59 hr:min 1 minute
NORM, GAUG Dive Number 0 to 24 1 (dive)
NORM, GAUG Log Entry Number 0 to 99 1 (dive)
NORM, GAUG Elapsed Dive Time 0:00 to 9:59 hr:min 1 minute
NORM Dive Time Remaining 0:00 to 9:59 hr:min 1 minute
NORM, GAUG Gas Time Remaining 0 to 99 min 1 minute
FO2 Set Point (Gas 1, 2, 3, 4) Air, 21 to 100 % 1 %
PO2 (current value) 0.00 to 5.00 ATA .01 ATA
O2 Saturation 0 to 100 % 1 %
No Deco Deep Stop Time 2:00 to 0:00 min:sec 1 second
No Deco Safety Stop Time 5:00 to 0:00 min:sec 1 second
No Deco Safety Stop Run Timer 0:00 to 9:59 min:sec 1 second
GAUG Dive Run Timer 0:00 to 9:59 min:sec 1 second
0:10 to 9:59 hr:min 1 minute
Deco Stop Time 0:00 to 9:59 hr:min 1 minute
Deco Total Ascent Time 0:00 to 9:59 hr:min 1 minute
Violation Countdown Timer 23:50 to 0:00 hr:min 1 minute
SPECIFICATIONS (CONTINUED)