Oceanic 4.6271 Scuba Diving Equipment User Manual


 
36
VTX OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5382-r01 (10/24/14)
SET TMT MENU (NORM, GAUG), previously described on page 19.
SET ALARMS MENU (GAUG), information includes (Fig. 64):
Selections with their last Set points saved include:
> AUDIBLE = with ON or OFF.
> DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05. EDT is Elapsed Dive Time.
> TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR). TURN is pressure of TMT 1.
> END = with 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR). END is pressure of the TMT in use.
A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
M (< 2 sec) - to step back (up screen) through Menu selections.
S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
A (< 2 sec) - to toggle or increase the set point.
A (hold) - to increase the set point at a rate of 8 per second.
M (< 2 sec) - to toggle or decrease the set point.
S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
SET UTILITIES MENU (GAUG), information includes (Fig. 65):
Selections with their last Set points saved include:
> WATER = with FRESH or SEA.
Depth values will be based on the type of water
.
> UNITS = with IMPERIAL or METRIC.
> SAMPLING = with 2, 15, 30, or 60 SEC (second).
Rate that data is sampled and recorded for PC download
.
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
M (< 2 sec) - to step back (up screen) through Menu selections.
S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
A (< 2 sec) - to toggle or increase the set point.
A (hold) - to increase the set point at a rate of 8 per second.
M (< 2 sec) - to toggle or decrease the set point.
S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
GAUG DIVE PREVIEW, information includes (Fig. 66):
Upon accessing this screen from the GAUG MENU, the items illustrated will be displayed with the settings last saved.
Turn and End Alarms will not be displayed unless a TMT is in use.
S or M (2 sec) to step back to the GAUG MENU with VIEW PREVIEW highlighted.
Fig. 64 - SET ALARMS
Fig. 65 - SET UTILITIES
Fig. 66 - VIEW PREVIEW
GAUG SET ALARMS
AUDIBLE =
EDT =
TURN =
END =
DEPTH =
ON
150 FT
0:40
1500 PSI
300 PSI
GAUG SET UTILITIES
WATER =
SAMPLING =
UNITS =
15 SEC
FRESH
METRIC
DEPTH AL =
EDT AL =
TURN AL =
END AL =
WATER =
GAUG DIVE PREVIEW
150 FT
0:40
1500 PSI
300 PSI
FRESH