5. BASE SPECIFICATIONS PARAMETERS
II - 65
# Items Details Setting range (unit)
1233 set05
(bit1)
Spindle clamp
selection
Select whether to validate the spindle override for
the spindle speed clamp command (G92 S?).
0: Spindle override invalid
1: Spindle override valid
0/1
1234 Not used.
1235 set07
(bit2)
Fixed type
chopping
compensa-
tion valid only at
start
When the fixed type compensation value is
selected, the method is changed to the
compensation value sequential update type after
the first four cycles.
0: Method changeover invalid
1: Method changeover valid
0/1
1236 set08
(bit0)
Manual rotation
axis feedrate
unit
Select the unit of manual rotation axis feedrate.
0: Fixed to [°/min]
1: Same speed as before
0/1
set08
(bit1)
Spindle speed
detection
Select the pulse input source of actual spindle
rotation speed output (R18/19) when spindle
encoder serial connection (#3025 enc-on: 2) is
selected.
0: Serial input
1: Encoder input connector
0/1
set08
(bit2)
Current limit
droop cancel
invalid
Set whether to cancel the position droop when the
current limit changeover signal is canceled.
0: Cancel droop.
1: Do not cancel droop.
0/1
1237
(PR)
set09
(bit0)
External
workpiece offset
Set up this function to use the external workpiece
coordinates by shifting them to the Z axis.
0: Does not reverse the sign of external
workpiece offsets (Z shift) (same as before).
1: Reverses the sign of external workpiece
offsets (Z shift).
Note: When the sign of external workpiece offsets
(Z shift) has been reversed, do not measure
those external workpiece offsets. However,
the external workpiece offsets can be
measured by tool pre-setter.
0/1