2. OPERATION MESSAGES ON SETTING AND DISPLAY UNIT
2.1 Operation Errors
I - 53
Error No. Error message Details
E201 UNIT NOT EQUIP
×
• The analog output unit is not mounted.
• Confirm the remote l/O unit.
• Prepare a unit having analog output.
• Check the connection (power and signal wires)
• Unit defect (replace unit)
E301 CONNECT
ERROR
×
• A socket connection attempt failed during Ethernet
communication. Check the host address, the setting of the port
No. and that the host computer is turned ON.
E302 LOGIN ERR
×
• A login attempt failed during Ethernet communication. Check the
user name and password.
• Check the account settings, such as the home directory.
E303 TIME OUT
×
• Transmission of a file with Ethernet communication ended
because of timeout.
E311 DOWNLOAD ERR
×
• An attempt to read a host file failed during Ethernet
communication.
E312 UPLOAD ERR
×
• An attempt to write to a host file failed during Ethernet
communication.
E313 NO FILE
×
• Specified file (transmission source file) is not found.
(Not exist in the transmission source device.)
E314 FILE DUPLICATE
×
• A file having the same name as the one to be sent exists in the file
destination.
In the IC CARD I/O screen, overwriting is possible with
"Y"+INPUT.
E315 FILE WRITE ERR
×
• An attempt to write to the IC card failed.
E316 FILE READ ERR
×
• An attempt to read a file from the IC card failed.
E317 MEMORY OVER
×
• IC card memory is full.
• NC memory is full.
E318 OVER FLOW ERR
×
• A host directory contains too many files.
E319 DIRECTORY ERR
×
• An attempt to move a directory failed.
• In the IC card device, accessing a directory in the nineteenth
layer or more was attempted.