6. AXIS SPECIFICATIONS PARAMETERS
6.4 Axis Specifications Parameters 2
II - 96
(SETUP PARAM 2. 7/8)
# Items Details Setting range (unit)
2073 zrn_dog Origin dog Under the standard specifications, the origin dog signal
is assigned to a fixed device. When it is desired to
assign the origin dog signal to a position other than the
fixed device, specify the input device in this parameter.
Note 1: This parameter is valid when 1 is set in #1226
aux10 bit 5.
Note 2: When this parameter is valid, do not set the
same device number. If the same device
number exists, an emergency stop occurs.
However, no device number check is performed
for an axis to which a signal that ignores the
near-point dog signal (R157) is input.
00 to FF (HEX)
2074 H/W_OT+ H/W OT+ Under the standard specifications, the OT (+) signal is
assigned to a fixed device. When it is desired to assign
the OT (+) g signal to a position other than the fixed
device, specify the input device in this parameter.
Note 1: This parameter is valid when 1 is set in #1226
aux10 bit 5.
Note 2: When this parameter is valid, do not set the
same device number. If the same device
number exists, an emergency stop occurs.
However, no device number check is performed
for an axis to which a signal that ignores the OT
signal (R156) is input.
00 to FF (HEX)
2075 H/W_OT- H/W OT- Under the standard specifications, the OT (-) signal is
assigned to a fixed device. When it is desired to assign
the OT (-) g signal to a position other than the fixed
device, specify the input device in this parameter.
Note 1: This parameter is valid when 1 is set in #1226
aux10 bit 5.
Note 2: When this parameter is valid, do not set the
same device number. If the same device
number exists, an emergency stop occurs.
However, no device number check is performed
for an axis to which a signal that ignores the OT
signal (R156) is input.
00 to FF (HEX)
2076 index_x Index
table
indexing
axis
Specify the index table indexing axis.
0: Normal axis
1: Index table indexing axis
Note: This parameter is valid only for the NC axis. The
parameter is invalid if specified for the PLC axis.
0/1
2077 G0inps G0
in-position
width
When an in-position check is performed for G0, this
parameter is valid.
(Comparison of SV024 and this parameter, the
parameter that the in-position width is wider is applied.)
When 0 is set, this parameter is invalid.
(Applicable only to SV024)
0 to 32767 (ยตm)