5. BASE SPECIFICATIONS PARAMETERS
II - 70
# Items Details Setting range (unit)
1273
(PR)
ext09
(bit0)
Switch ASIN
calculation
results range
Select the ASIN calculation results range.
0: –90° to 90°
1: 90° to 270°
0/1
ext09
(bit1)
Switch system
variable unit
Select the unit for the system variable #3002 (time
during automatic start).
0: 1ms unit
1: 1 hour unit
0/1
ext09
(bit2)
Switch G71,
G72, G73
cutting direction
judgment
Select whether to determine the cutting direction
with the finished shape, or according to the
commanded finishing allowance and cutting
allowance when the longitudinal rough cutting cycle
(G71), face rough cutting cycle (G72) or closed loop
cutting cycle (G73) is commanded.
0: Conventional specifications
Determined according to the finished shape
program.
1: Extended specifications
Determined according to the finishing
allowance and cutting allowance commanded
in the program.
0/1