ACR Electronics Y1-03-0203 Marine RADAR User Manual


 
User Manual 55 Y1-03-0203 Rev.L
Dynamic Keys: Replying to a LR Interrogation
[M5]
[OK]
Notifies User of
current
interrogation
[M8]
[Back]
Return to
Vessel Listing
[M7]
[Reply]
Display
Message Editor
for LRI Reply
Sensor Settings
The screen provides the means to switch the sensor speeds. It allows the user to change sensor
interfaces from IEC61162-1 to IEC61162-2 settings. The data input fields are fitted with default
values. The [Up], [Down] buttons are used for menu navigation, the [Left] or [Right] buttons for
default data input.
Sensor Software Configuration (Service Password protected)
This is new in software version 2.0.1.x. The NAUTICAST offers the following configuration options:
Set up data speed 4800/9600/38400 baud.
Monitor the connected sensor inputs for each sensor channel.
Verify and edit the Sensor Configuration on the display screen.
Analyze the information received from the connected sensor devices.
Produce an electronic installation report.
Configuration of various NMEA protocols.
Dynamic Keys: Sensor Settings
[M5]
[Save]
Save Data Input
[Up] /
[Down]
Select Data Field
for Configuration
[M6]
[Default]
Restore the
default settings
[Enter]
Select Data Field
for Configuration
[M7]
[Analyce]
Analye you NMEA
Data streem
[Left] /
[Right]
Configure Data
[M8]
[Back]
Return to Menu
Configuration
N 1
o
19' E 0
o
12' |1> N/A|2>0.00|3>0.10nm
*********** Sensor Settings ************
BaudRate Sensor1:< 4800> CRC: auto
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
1>Start Monitor>
BaudRate Sensor2: 4800 CRC: auto
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
2>Start Monitor>
BaudRate Sensor3: 38400 CRC: auto
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
3>Start Monitor>
----------------------------------------
| Save | Default | Analyze | Back