Emerson MAS 2600 Marine Instruments User Manual


 
Installation & User Manual
June 2013 Ed 19UK
Page 9 of 28
Class approved
Sea valve
TWO WIRE TRANSMITTER
2600 SERIES
90-C.95948
T5
Cint = 10 nF
C
CERTIFICATE REF.:
4-20 mA
Lint = 20 uH
x
i
EE
X
a
MARINE AUTOMATION DENMARK
S/N:
Umax = 33 V
T
amb.: -40 to +85 °C
I 45 mA
K=
<
2600
Weather deck
MAS2600 amplifier box
Sensor pos. above
Ships hull
Ships hull
Vent pipe min. 1”
Min. draft
Draft
:
Transducer measuring range > max. draft minus sensor position.
This rule applies provided the transducer is mounted in accordance with the installation drawing
for draft transmitters (vent pipe min. 1"). The sensor may be mounted direct on the sea valve with
an air release valve if the ship is sailing in calm waters.
If the transducer is installed in tanks which may have excessive dynamic stresses such as e.g.
high pump pressure, long bottomed tanks with a risk of slashing etc., contact Emerson Process
Management Marine Solutions, Damcos.
Temperature Sensor MAS2600-XXX-XX-X/XX
The transducer can be supplied with a built-in Pt100 temperature sensor. The temperature sensor
will only give a proper reading, if the transducer is an internally mounted type.
0: Without temperature sensor.
1: With temperature sensor
Cable MAS2600-XXX-XX-X/XX
Two types of transducer cable is available. The standard cable for applications with temperatures
never exceeding 80°C, and high temperature cable for applications with temperatures up to
125°C. The transducer cable is delivered in whole meters.
For further information require data sheet.
To make the MAS2600 transmitter easy to install, and for later service purposes, the transducer
cable should be as short as possible, though considering the position of the transducer and
amplifier box.
Max. cable length: 300 m.
When installing in hazardous areas max. cable length: 75 m.