Furuno 1723c Marine RADAR User Manual


 
1-9
9. Attach EMI core (supplied) to antenna cable between cable ties. Set the fixing band to
the EMI core.
This bend should be
facing toward you.
Fixing band
Fixing band
10. Referring to the figure of "How to connect the antenna cable to the antenna Unit" on the
previous page connect the 9-pin (J801) and 10-pin (J811) connectors of the antenna
cable to the INT Board.
11. Refasten the shield plate with 10 screws. Be sure not to pinch cable from the rotation
detector with the shield plate. See "Caution" in the figure of "Antenna unit, inside view"
on page 1-7, for details.
12. Fasten the fixing band with screw (M4X15; supplied).
Screw(M4X15)
EMI core
Fixing
band
Align bend with
corner of chassis.
How to fix the EMI core
13. Follow the instructions on the label inside the mounting base to secure the snap assy.
14. Confirm that the rubber gasket is properly positioned and that the triangle mark on the
radome cover is aligned with the triangle mark on the mounting base, then tighten the
fixing screws for the cover. Refer to the figure of sectional view on the previous page for
positioning of rubber gasket.