Furuno 1723c Marine RADAR User Manual


 
3-7
PUSH SOFTKEY 'SET' AFTER
ADJUSTING HEADING LINE.
RETURN
SET
Heading adjustment setting display
5. Rotate the [ENTER] knob to bisect the target with the EBL.
6. Press the SET soft key.
7. As a final test, move the boat towards a small buoy and confirm that the buoy shows up
dead ahead on the radar when it is visually dead ahead.
3.3.5 HEADING DATA
Select the heading reference, MAGNETIC or TRUE. Select MAGNETIC when connecting
with the magnetic compass, select TRUE when connecting with the gyrocompass. For your
reference, when connecting with Satellite Compass SC-60/120 or Integrated Hading Sensor
PG-1000 which Furuno makes, set the heading data as the table shown below.
Model Setting of HEADING DATA
with L/L data TRUE
PG-1000
w/o L/L data MAGNETIC
SC-60/120 TRUE
1. Open the RADAR SETUP menu and then select HEADING DATA.
2. Press the EDIT soft key or [ENTER] knob to show the setting window.
HEADING DATA
MAGNETIC
TRUE
Heading data setting window
3. Select MAGNETIC or TRUE.
4. Press the [ENTER] knob or ENTER soft key.