4. INSTALLATION
36
Matching box MB-1100
*: With 10P connector cable
**: For connecting two transducers
Fabricating the transducer cable
Fabricate the transducer cable as below and
connect it to the matching box.
How to fabricate the transducer cable
4.9 IEC 61162-1 Data
Sentences
The table below shows the data sentences
which can be input to and output from the
FCV-620/585. The transmission speed for
both input and output is 4,800 bps. Data is
transducer cableoutput at two-second inter-
vals.
Input data sentences (con’t)
Order of priority
Latitude/Longitude: GGA>RMC>RMA>GLL
Course (true): VTG>RMC>RMA
Course (magnetic): VTG
Ground speed: VTG>RMC>RMA
Water speed: VHW
Distance to waypoint: BWC>RMB
Bearing to waypoint (true): BWC>RMB
Bearing to waypoint (magnetic): BWC
Heading (true): HDT>VHW
Heading (magnetic): HDG>VHW
Cross track error: XTE>RMB
Atmospheric pressure: MDA
Water temperature: MTW
Wind speed and angle (true/apparent): MWV
*= Available with connection of optional sen-
sors/navaid
Part Type Code No. Qty
Matching
Box*
MB-1100 000-041-000 1
Crimp-on
Lug
FV1.25-3,
red
000-538-113 6
Cord Lock** NC-1 000-516-650 1
Input data sentences
Sentence Meaning
BWC Bearing and distance to waypoint.
GGA Global positioning system (GPS)
fix data.
GLL Geographic position - latitude/lon-
gitude.
HDG Heading, deviation and variation.
HDT Heading, true.
MDA Atmospheric pressure.
MTW Water temperature.
Crimp-on Lug
FV1.25-3, Red
Taping
Vinyl Sheath
Shrink Tubin
g
Shield
MWV Wind speed and angle.
RMA Recommended minimum specific
LORAN-C data.
RMB Recommended minimum naviga-
tion information.
RMC Recommended minimum specific
GPS/TRANSIT data.
VHW Water speed and heading.
VTG Course over ground and ground
speed.
XTE Cross track error.
Output data sentences
Sentence Meaning
DBT (Ver. 1.5) Depth below transducer
DPT (Ver. 2.0,
Ver. 3.0)
Depth
MTW* Water temperature
VHW* Water speed and heading
TLL* Target position, output by
MARK key.