Furuno 585 SONAR User Manual


 
FURUNO
FCV-620/585
SP - 2 E2374S01B-M
3. INTERFACE
3.1 Input Data Sentences IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0)
Order of priority
Latitude/Longitude: GGA>RMC>RMA>GLL
Course (true): VTG>RMC>RMA
Course (magnetic): VTG
Ground speed: VTG>RMC>RMA
Water speed: VHW
Distance to waypoint: BWC>RMB
Bearing to waypoint (true): BWC>RMB
Bearing to waypoint (magnetic): BWC
Heading (true): HDT>VHW
Heading (magnetic): HDG>VHW
Cross track error: XTE>RMB
Atmospheric pressure: MDA
Water temperature: MTW
Wind speed and angle (true/apparent): MWV
3.2 Output Data Sentences IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0), interval: 2 s
DBT, DPT, MTW*, VHW*, TLL* by key operating
*: External data required
4. POWER SUPPLY
4.1 FCV-620 12-24 VDC: 0.8-0.4 A
4.2 FCV-585 12-24 VDC: 1.0-0.5 A
5. ENVIRONMENTAL CONDITION
5.1 Ambient Temperature -15 °C to +50 °C
5.2 Relative Humidity 93 % at 40 °C
5.3 Waterproofing IP55
(IEC60529)
5.4 Vibration 2-5 Hz and up to 13.2 Hz with an excursion of ±1 mm ±10 %
(7 m/s
2
maximum acceleration at 13.2 Hz)
13.2-100 Hz with a constant maximum acceleration of 7 m/s
2
6. CHASSIS COLOR
6.1 Display Unit Chassis: N-2.5
Bracket: N-1.75