Furuno CSH-84 SONAR User Manual


 
4-7
4.5 Cable Fabrication and Connector Assembling in
Power Unit
Assembling 38P connector (CN-E1)
Fabrication of cable 10S1260
45
40
200
Vinyl sheath
Shield
Armor
Anticorrosive sheath
Core
Insulating tape
Fold back shield
onto armor.
Figure 4-9 Fabrication of cable 10S1260
Assembling the 38P connector
1. Bundle unused wires outside the connector case.
2. Fix the cover 1, noting the cable outgoing direction.
3. Dress the wires and fix the covers 2 and 3. Use a fragment of
cable sheath to fix the wires at the cable clamp.
4. Shorten unused wires and tape their ends with vinyl tape to prevent
short circuit.
Position No.
Guide Pin A
(Large)
Guide Pin B
(Small)
Cover 1
Insulate unused
wires with vinyl
tape.
Fragment of
anticorrosive sheath
Guide pin
Cover 3
Guide Pin A Guide
Pin B
Cover 2
Figure 4-10 How to assemble the 38P connector
A
TT
Cable outgoing
direction