Furuno FCR-2107 Marine RADAR User Manual


 
22. Maintenance and Troubleshooting
22-5
22.5 Troubleshooting
The troubleshooting table below provides common faults and the remedy with which to restore normal operation. If
you cannot restore normal operation do not check inside the equipment - there are no user-serviceable parts inside.
Radar troubleshooting
If… Then… Remedy
the power cannot be turned on
power connector may have
loosened.
ship’s mains is off.
fuse has blown.
Check connector.
Check ship’s mains.
Replace fuse.
the power can be turned on but
nothing appears on the display
brilliance is too low.
the ambient temperature is less
than 0
°C (32°F).
Adjust brilliance.
The heater is warming the chart
processor unit. The display
appears in approx. 10 minutes.
key doesn't beep when operated
key beep is turned off. Turn on key beep from the menu.
Picture not updated or picture
freeze.
suspect video freeze. 30 seconds
after the picture freezes the
buzzer sounds, the ALARM
ACK key blinks and alarm
signal is output.
Turn the power off and on again.
marks and noise appear but no
echoes
fuse may have blown. Check fuse in processor unit.
picture does not change even
though range is changed.
suspect faulty range key or video
freeze.
Hit the RANGE key several
times. If nothing happens, turn
the power on and off again.
only two index lines are displayed
check index line interval setting. Refer to section 2.20
Parallel
Index (PI) Lines
for how to adjust
index line interval.
range rings are not displayed
range rings are turned off. Turn on the range rings from the
Color menu.
ARP target is not tracked correctly
sea surface reflections, etc. are
masking ARP target.
Adjust A/C SEA and A/C RAIN
to suppress sea and rain clutters.
sensitivity is poor
suspect 2
nd
trace echo or soiled
radiator.
Remove 2
nd
trace echo; clean
radiator.