5. ALARMS
5-5
3. Rotate the [ENTER] knob to select speed alarm condition.
OFF: Turn the speed alarm off.
OVER: The alarm is released when the ship’s speed is over the set value.
UNDER: The alarm is released when ship’s speed is under the set value.
INSIDE: The alarm released when ship’s speed is within the range set.
OUT OF RANGE: The alarm is released when ship’s speed is outside the range
set.
When selecting INSIDE or OUT OF RANGE, set the upper and lower limits,
using three digits. For OVER and UNDER, set value (Setting range: 0.0 to 999.9
kt, km/h or mph).
4. Press the [ENTER] knob.
5.1.7 Setting the depth alarm
The depth alarm sounds when the bottom is shallower, deeper, within or outside
the range set. To activate the depth alarm, the depth data is necessary.
1. Rotate the [ENTER] knob to select “DEPTH ALARM” from the ALARM menu.
2. Press the [ENTER] knob to show the depth alarm options window.
SHALLOW
DEEP
INSIDE
OUT OF RANGE
OFF
Depth alarm options window
3. Rotate the [ENTER] knob to select the condition.
OFF: Turn the depth alarm off.
SHALLOW: The alarm is released when the bottom is shallower than the value
set.
DEEP: The alarm is released when the bottom is deeper than the value set.
INSIDE: The alarm is released when the bottom is within the range set.
OUT OF RANGE: The alarm released when the bottom is outside the range set.
When selecting INSIDE or OUT OF RANGE, set upper and lower limits, using
three digits. For SHALLOW or DEEP, set a value (Setting range: 0 to 999.9
ft/m/FA/PB).
4. Press the [ENTER] knob.