B.5 Shield Termination-Method B.2 (Daisy Chain-Quick Term)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure B-6). All other restrictions and instructions for the shield termination technique set forth for
Method A.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure B-6 Method B.2 (Daisy Chain-Quick Term) for Shield Termination
Table B-4 Shielded Cable Preparations – (Quick Term)
Backshell Size
Number of Pins
Std/HD
Quick Term Min
(inches)
Quick Term Max
(inches)
Quick Term
Float (inches)
1 9/15 1.25 2.25 1.75
2 15/26 1.5 2.5 2.0
3 25/44 1.5 2.5 2.0
4 37/62 1.5 2.5 2.0
5 50/78 1.5 2.5 2.0