Graco 3A0869J Outboard Motor User Manual


 
System Errors
3A0869J 57
Error Codes
Table 5: System Alarm/Advisory/Record Codes
Code Description Details
Alarm Codes - Alarm sounds, system stops, icon dis-
plays until problem is solved and alarm is cleared.
CA Communication Error 43
CAU1 USB Communication Error 43
EQU2 USB Installed when not in Standby 43
SG Gun Flush Box Error 43
SAD1
SAD2
Atomizing Air During Purge - Gun 1
Atomizing Air During Purge - Gun 2
43
SPSA
SPSB
Purge Volume Error A
Purge Volume Error B
SFA1
SFA2
SFA3
SFB1
PreMix Error - Color
PreMix Error - Catalyst
43
SHA1
SHA2
SHA3
SHB1
PreFill Error - Color
PreFill Error - Catalyst
43
SM MixFill Start Error 44
SN MixFill Complete Error 44
QPD1
QPD2
Potlife Error - Gun 1
Potlife Error - Gun 2
44
R1 Ratio Low Error 44
R4 Ratio High Error 45
QDA1
QDA2
QDA3
QDB1
Overdose A, B Dose too Short
Overdose B, A Dose too Short
46
QTA1
QTA2
QTA3
QTB1
Dose Time A Error
Dose Time B Error
47
QLAX
QLBX
Leak Error A
Leak Error B
47
P6A1
P6B1
Pressure Transducer Error A
Pressure Transducer Error B
48
Advisory Codes - No alarm, system continues operat-
ing, icon displays on active screen until cleared
MFA1 Meter A maintenance due N/A
MFB1 Meter B maintenance due N/A
MEA1 Mix valve A1 maintenance due N/A
MEA2 Mix valve A2 maintenance due N/A
MEA3 Mix valve A3 maintenance due N/A
MEB1 Mix valve B maintenance due N/A
MESA Solvent valve A maintenance due N/A
MESB Solvent valve B maintenance due N/A
MGA1 Fluid Filter A maintenance due N/A
MGB1 Fluid Filter B maintenance due N/A
MGP1 Air Filter maintenance due N/A
ES System defaults loaded N/A
Record Codes - No alarm, system continues operating,
no icon displays on active screen.
EL System powered on N/A
EC System setup changed N/A
ES System defaults loaded N/A
ET System performed an autodump after
a potlife
N/A
EQU1 USB Drive connected while in Standby N/A
Table 5: System Alarm/Advisory/Record Codes
Code Description Details