HP (Hewlett-Packard) HP NetRAID-4M Life Jacket User Manual


 
HP NetRAID-4M Cluster Services Installation Guide Hardware, Drivers and Utilities
7
11. Connect one end of a 10BaseT Crossover cable to the HP D5013B NIC that was just
installed into Server A.
12. DO NOT connect the HP NetRAID-4M controller SCSI cables at this time.
13. Repeat the above steps, 1 through 8 to add the HP NetRAID-4M and HP D5013B NIC to
Server B.
14. Close Server B, and if working on a racked server, slide the server back into the rack
enclosure, and then reconnect all cables.
15. Connect the other end of the 10BaseT Crossover cable to the second HP D5013B NIC in
Server B.
CAUTION DO NOT connect the HP NetRAID-4M controller SCSI cables at this time.
Update the NetRAID-4M Firmware
16. Flashing from diskette -- At Server A, insert the HP NetRAID-4M firmware update
diskette in the floppy drive and power the server on. Do not power on Server B at this
time. Go to step 17.
Or
Flashing from CD-ROM --NetRAID-4M firmware can be flashed without diskettes by
booting from the HP NetServer Navigator CD-ROM. The sequence of menu selections is:
Configure the Server, Custom Setup, BIOS and Firmware Update, HP NetRAID-4M
Adapter(D9161/D9351A).
If the firmware listed under Version on server IS the latest supported version, remove the
CD, power off the server, and skip to step 26, otherwise, if the Version on CD is desired,
check the box next to HP NetRAID-4M Adapter (D9161/ D9351A), Continue, Choose
Language, Continue. Skip to step 26.
17. When the NetRAID-4M banners on the screen, note the firmware or build version, for
example:
NetRAID-4M BIOS v.2.4-0 [Build 4584]
18. If the firmware IS the latest supported version, remove the floppy, power off the server,
and skip to step 26, otherwise, proceed to the next step to update the firmware.
19. If prompted with a message that the SCSI IDs are not responding, press Enter.
20. When the server has booted to the HP NetRAID-4M firmware update diskette 1, select
Update NetRAID Flash Image.
21. Tab to select OK and press Enter to accept A:\ as the directory for the flash image file.
22. When prompted, insert the HP NetRAID-4M firmware update diskette 2 into the floppy
drive of the server and press Enter.
CAUTION DO NOT power off or reboot the server during the firmware update. If this
should occur, the NetRAID-4M card will be made inoperable.
23. Select OK to NOT reboot the server.