FUNCTION LIST
MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS
= Allowed
= Not permitted
Code Function Name Monitored data or setting
Default Setting
Setting
during
operation
(allowed or not)
Change
during
operation
(allowed or not)
SJ700/SJ700D(CTmode)
SJ700B
-FE -FU -F -F -FU
Monitor Mode
d001
Output frequency monitor
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
----- -
d002
Output current monitor
0.0 to 999.9, 1000 to 9999 (A)
----- - -
d003
Rotation direction minitoring
F (forward rotation), o (stopped), r (reverse rotation)
----- - -
d004
Process variable (PV), PID feedback monitor
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999. 1000 to 9999 (10000 to 99990),
100 to 999 (10000 to 999000)
----- - -
d005
Intelligent input terminal status
(Example) FW, 7, 2, 1 : ON
8, 6, 5, 4, 3 : OFF
----- - -
d006
Intelligent output terminal status
(Example) 12, 11 : ON
AL, 15, 14, 13 :OFF
----- - -
d007
Scaled output frequency monitoring
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999., 1000 to 3996 (10000 to 39960)
----- -
d008
Actual-frequency monitoring
(*3) -400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
---- - - -
d009
Torque command monitoring
(*3) -200. to +200. (%)
----- - -
d010
Torque bias monitoring
(*3) -200. to +200. (%)
----- - -
d012
Torque monitoring
-200. to +200. (%)
----- - -
d013
Output voltage monitoring
0.0 to 600.0 (V)
----- - -
d014
Power monitoring
0.0 to 999.9 (kW)
----- - -
d015
Cumulative power monitoring
0.0 to 999.9, 1000. to 9999.,1000 to 9999 (10000 to 99990), 100 to 999 (100000 to 999000)
----- - -
d016
Cumulative operation RUN time monitoring
0. to 9999., 1000 to 9999 (10000 to 99990), 100 to 999 (10000 to 999000) (hr)
----- - -
d017
Cumulative power-on time monitoring
0. to 9999., 1000 to 9999 (10000 to 99990), 100 to 999 (10000 to 999000) (hr)
----- - -
d018
Heat sink temperature monitoring
-020. to 200.0 (℃)
----- - -
d019
Motor temperature monitoring
-020. to 200.0 (℃)
----- - -
d022
Life-check monitoring
1: Capacitor on main circuit board
2: Cooling-fan speed drop
----- - -
d023
Program counter
0 to 1024
----- - -
d024
Program number monitoring
0000 to 9999
----- - -
d025
User monitor 0
-2147483647 to 2147483647 (upper 4 digits including “-“)
----- - -
d026
User monitor 1
-2147483647 to 2147483647 (upper 4 digits including “-“)
----- - -
d027
User monitor 2
-2147483647 to 2147483647 (upper 4 digits including “-“)
----- - -
d028
Pulse counter
0 to 2147483647 (upper 4 digits)
----- - -
d029
Position setting monitor
(*3) -1073741823 to 1073741823 (upper 4 digits including “-“)
----- - -
d030
Position feedback monitor
(*3) -1073741823 to 1073741823 (upper 4 digits including “-“)
----- - -
d031
Clock monitor
(SJ700D only) * In case you use WOP (option), this monitor is activated.
--- --
d060
Inverter mode monitor
(SJ700D only) I-C (CT)/ I-v (VT)
--- --
d080
Trip Counter
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
----- - -
d081
-
d086
Trip monitoring 1-6
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
----- - -
d090
Programming error monitoring
Warning code
----- - -
d102
DC voltage monitoring
0.0 to 999.9 (V)
----- - -
d103
BRD load factor monitoring
0.0 to 100.0 (%)
----- - -
d104
Electronic thermal overload monitoring
0.0 to 100.0 (%)
----- - -
Setting Mode
F001
Output frequency setting
0.0, "start frequency" to "maximum frequency" (or maximum frequency,
2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.00 0.00 0.00 0.00 0.00
F002
Acceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F202
Acceleration (1) time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F302
Acceleration (1) time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F003
Deceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F203
Deceleration time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F303
Deceleration time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00 30.00 30.00 30.00 30.00
F004
Keypad Run key routing
00 (forward rotation), 01 (reverse rotation)
00 00 00 00 00
Expanded Function
A---
A Group: Standard functions
b---
b Group: Fine tuning functions
C---
C Group: Intelligent terminal functions
H---
H Group: Motor constants functions
P---
P Group: Expansion card functions
U---
U Group: User-selectable menu functions
(*1) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz) (*2) 4000HF: -120. to -100., -99.9 to 0.00 to 99.99,100.0 to 120.0 (Hz)
(*3) SJ700D (VT): Not available (no display)
FW
5487 2361
ON
OFF
AL
1213 1115 14
ON
OFF
21
ON
OFF
14