MENU
ATA (Automatic Tracking Aid)
DATA
OFF :Turn the ATA function OFF.
ON :Turn the ATA function ON.
DNo.DISP
OFF :Non display any mark number.
Sel :Display the selected mark number
only.
ALL :Display all mark numbers.
DVECT
TRUE :Select the true vector mode.
REL :Select the relative vector mode.
DOWN VECT
OFF :Non display the own ship vector.
ON :Display your own ships vector.
DALARM (CPA/TCPA)
OFF :Turn the alarm function OFF.
ON :Turn the alarm function ON.
DCPA* LIMIT
0.1 to 10.0NM :Set the CPA (Closest Point of Ap-
proach) limit with [
Ω≈
].
DTCPA* LIMIT
1 to 60MIN :Set the TCPA (Time to CPA) limit time
with [
Ω≈
].
*CPA/TCPA: Closest Point of Approach and Time to Clos-
est Point of Approach limit is dened by the observer to
given warning when a target or targets are close to
within those limits from your own ship.
INT. SETTING
DMAG VAR
AUTO :Revise magnetic variation automatically.
NOTE: NMEA data is required. NEVER select
AUTO without NMEA data, incorrect varia-
tion data may entered. (p. 39)
MANUAL :Revise magnetic variation manually.
Push [
] to select [MANUAL], then push
[Ú]. Set the revise value with [
Ω≈
].
Push [Ú] or [MENU] to abort the menu.
DBRG INPUT
NMEA :NMEA0183 bearing data format.
N+1 :N+1 data format.
AUX :Other format.
GPS :Reads NMEA0183 COG format data as
HDG format.
DSPD INPUT
GPS :Use the GPS NMEA speed data.
LOG :Use the speed sensor data.
DTX INH START
0 to 359° :Push [
Ω≈
] to enter the start point of the
TX inhibit area.
DTX INH ANGLE
0 to 90° :Push [
Ω≈
] to enter the TX inhibit area.
DSAVE TIME
1M, 6M, 15M or 30M
: Select the stand by time during save
mode.
* The radar for TX interval scan is xed at 10 revolutions.
DSYMBOL
1/2/3 : Select the symbol brightness.
DCHARACTER
1/2/3 : Select the character brightness.
DKEY ILLUM
1/2/3/4 : Select the key illumination brightness.
INT. SETTING
BRG INPUT
SPD INPUT
TX INH START
TX INH ANGLE
SAVE TIME
SYMBOL
CHARACTER BRILL
NMEA
30M
LOG
6M 15M
MANUAL
AUTO
N+1 AUX GPS
GPS
0
˚
0
˚
KEY ILLUM
MAG VAR
1 23
1 2 3
1234
7.2
˚
W
1M
ATA MENU
VECT
No.DISP OFF ALL
OWN VECT
ALARM
CPA LIMIT
TCPA LIMIT
TRUE
ON
ON
ON
OFF
REL
OFF
OFF
1.0NM
1 MIN
ATA