Icom MR-1000RTM Fish Finder User Manual


 
11
32
SERVICE MAN MENU
Service man menu
To open the SERVICE MAN menu.
Push [MENU]/[ ] several times to show the
SERVICE MAN menu.
Select the language
Menu screens can be displayed in 2 different
languages.
Selectable languages; ENGLISH, (CHINESE)
After opening the SERVICE MAN menu;
q Push [Ù] to show the present language.
w Push [
Ω≈
] to select desired language, then push
[Ú] to continue the setting.
e Push [MENU]/[ ] to exit the SERVICE MAN
menu.
DTIMING ADJ.
Corrects the distance.
DHDG ADJ.
Adjusts the electronic heading line adjustment.
DSPD ADJ.
Enter the pulse rate of the speed sensor.
DRANGE
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36,
48* : Choose the selectable screen range.
*MR-1000TII only
DSETUP MEMORY
The present setting value is displayed by pushing [
],
then select the desired item from RECALL and
SAVE using with [Ú].
q Push [
] to display RECALL and SAVE.
w Push [ÙÚ] to select RECALL or SAVE.
e Push [
].
•“SURE ? is displayed.
r Push [
] to perform.
t Push [
]
to cancel
.
When recall is performed without saving a setup, it
will become an initial value at the time of factory
shipments.
DOther readouts
OUTPUT VOLTAGE
: Shows the voltage level for the
scanner unit from the display unit.
HV (High voltage): Shows the voltage level in the
high-voltage unit in the scanner
unit.
MONITOR : Shows the voltage level for
checking the receiver unit opera-
tion.
HEATER :Shows the heater current.
MG :Shows the current level for the
Magnetron.
TX TIME :Shows the total transmitted time.
SERVICE MAN
SPD ADJ.
HDG ADJ. 0.0
˚
HV
SETUP MEMORY RECALL
RANGE
24000 MONITOR
HEATER
5731.0H
TX TIME
30.0
OUTPUT
ENGLISH
VOLTAGE
SAVE MG
340
75
3.0
0.55
TIMING ADJ.
1/8 3/4 2 6
1/4 1 3 8
1/2 1.5 4 12
16
24
32
36
48
CAUTION: The SERVICE MAN MENU is available
for service purposes only. DO NOT change any set-
ting on the menu, otherwise the equipment may not
operate at its original performance.
MR-1000R2_T2.qxd 04.2.24 10:22 Page 32